Building Inspection Clay Cross

Project Information

Project:
Claycross

Category:
Dimensional Survey and Structural Assessment

Summary

GCS was commissioned to carry out a dimensional survey and structural assessment of the warehouse within the building compound. The client would like to use the first floor of the warehouse as a restaurant / café.

The building was found with suspended timber floor joists, historical steel beams and cast-iron columns.

Structural assessments are carried out to determine the capacity of the members to ensure they are suitable for the proposed usage. Strengthening works and details were proposed to specific structural elements.

Similar Posts

  • Retaining Wall Inspection

    Project Information Project:Retaining Wall Inspection Category:Specific Structural Survey Summary We were commissioned by the client to carry out a specific structural survey of the retaining walls within the building plot. Following the surveyor’s report, concerns were raised on the structural integrity of 4 no. of retaining walls. The retaining walls were situated in front and…

  • Derby

    Project Information Project:Derby Category:Specific Structural Survey Summary We were commissioned by the client to carry out a specific structural survey of the building. The client has concerns about the structural integrity as various cracks were noticed to the external envelops and to the internal finishes. A specific structural survey report was produced to identify potential…

  • Sheffield

    Project Information Project:Sheffield Category:Structural Assessment Summary We were commissioned by the client to carry out a structural assessment of an existing steel beam within the building. The client has concerns on the existing detail and would like to ensure the existing steel beam has sufficient capacity. A site visit is carried out to capture the…

  • Matlock

    Project Information Project:Matlock Category:Specific Structural Survey Summary We were commissioned by the client to carry out a specific structural survey of the front porch and front retaining wall to the building. The client had concerns on the structural integrity of the front porch as the condition had noticeably deteriorated in the past decade. A specific…

  • Green End, Whitchurch

    Project Information Project:Green End, Whitchurch Category:Structural Condition Survey Summary The structure is a series of mixed used, commercial properties. Located in Whitchurch centre, the building is a two-storey high structural fronting Green End and a series of single storey structures to the rear of Green End. The proposal is to covert the first floor into…